产品在全国几十个煤业集团及矿山上使用,获得了较高的评价和赞誉。3、使用条件电缆使用环境温度为-40℃~+50;在25℃时湿度为95%;电缆敷设温度≥-10℃;电缆敷设时的弯曲半径MHYV≥10倍电缆外径,其余型号≥15倍电缆外径。

Flexible cable RVVT, RVV RVVTP resistance to bending RVVPT RVVT detail TRVV flexible cable, cable RVVTP RVVPT bending resistant cable type: TRVV connection and control using the flexible cable, widely used in dry or wet indoor, reciprocating bend free mobile no compulsory pull drag chain system. Such as machine tool processing equipment, logistics delivery system, port machinery, complete equipment installation engineering. Product features: according to customer requirements, color core or coding core. High quality PVC mix is adopted to reduce the requirement of cable outer diameter for installation space. The designed cycle bending life is 5 million times, and the actual use has exceeded 6 million times. Cable structure: conductor: using multi-strand fine ground and other fine twisted into a bundle conductor oxygen-free copper wire, conform to DIN VDE 0295 grade 6 insulation: high quality PVC mixture color: color line core or coding line core 3 core + yellow or green conductor sheathed: high quality PVC mixture color: black, grey, orange electrical characteristics: rated voltage U0 / U < 0.5 was 300/300 V p o. 5 was 300/500 V test voltage: 3000 V U meet DIN VDE 0281 part 2 temperature range: ℃ mobile installation: fixed installation: - 5 ℃ ~ + 70 ℃ and 30 ℃ ~ + 70 ℃ when continuous movement, the minimum bending radius: 7.5 x cable diameter
With the way
在交联聚乙烯绝缘高阻燃的基础上又开发了低烟无卤高阻燃隔氧层动力电缆,其低烟无卤性能符合国家标准GB/T17651.1.2和GB/T17650.1.2。这样本公司的交联聚乙烯动力电缆的整体水平低于国内领先地位。

适用于各种火灾危险性较大,消防安全重要性较高的场所,电气装置及控制系统。二、产品执行标准:企业标准耐火特性试验执行GB/T及IEC60331标准,阻燃特性试验执行GB/T标准三、使用特性:1.交流额定电压:U0/U450/750V。
下图为带动态惯量阻尼器的步进电机暂态特性的步进响应的比较。此种吸振阻尼器不会像反相制动方法那样,在产生超调后才制动,但也不会消除最初的超调量。此种动态惯量阻尼器可以改善步进电机高速区域的共振引起的转矩降低,也可以改善高速时的转矩和响应脉冲。利用驱动电路的改善半步进1-2相激磁的情况:阻尼以及定位时,利用2相激磁比1相激磁要好。所以两相步进电机使用半步进驱动的1-2相激磁时,停止相采用2相激磁,阻尼会变好。
执行标准:GB/T13879.93YD/T,适用范围:本产品适用于市内通信用。HYA铜芯实心聚烯烃绝缘铝塑粘结综合护套市内通信电缆管道。HYAC铜芯实心聚烯烃绝缘铝塑粘结综合护套自承式市内通信电缆架空。
耐火电缆/NHVV耐火电力电缆,耐火聚氯乙烯绝缘电缆适用于地下铁道、地下商场、大型购物中心、高层建筑等人口稠密、通风受限的场合。适用范围本产品适用于工频额定电压0.6/1kV及以下配电线路或工业装置中有耐火要求的固定敷设场所使用。
DJVP3V(R)22聚氯乙烯绝缘铝塑复合带绕包分屏聚氯乙烯护套钢带铠装计算机用屏蔽(软)电缆。DJVP3V(R)P3-22聚氯乙烯绝缘铝塑复合带绕包分屏总屏聚氯乙烯护套钢带铠装计算机用屏蔽(软)电缆。
在整个网络布线中应用一种布线方式,但两端都有RJ-45插口的网络连线无论是采用568A标准,还是568B标准,在网络中都是可行的。双绞线的顺序与RJ45头的引脚序号—一对应。10M以太网的网线使用1、2、3、6编号的芯线传递数据,而100M网卡需要使用四对线。

Sheathed control cable products use feature: the cable conductor of long term working temperature should be allowed no more than 70 ℃. When the cable temperature under installation should not below 0 ℃, when laying bending radius should not less than 10 times of cable diameter. The cable with armor layer or copper band shielding structure shall not be less than 12 times the outer diameter of the cable.
本厂专业生产电力电缆,YJV,YJVR,RVV质量保证不亏方,外护套质量要求高电力电缆的使用至今已有百余年历史。1879年,美国发明家T.A.在铜棒上包绕黄麻并将其穿入铁管内,然后填充沥青混合物制成电缆。
跳跃闭锁继电器的电流启动值。电气防跳回路通常选用电流型动作线圈跳跃闭锁继电器,作为电流启动。根据电力工业部1984年反事故措施和电力系统二次回路设计规程规定,跳跃闭锁继电器的电流启动值应与断路器的跳闸电流配合,其电流启动值不得大于断路器跳闸电流的50%。也就是说跳跃闭锁继电器电流线圈动作值按断路器跳闸电流选择,以保证继电器的灵敏度。当断路器跳闸电流改变时,必须更换相应规格的跳跃闭锁继电器,这也就是为什么保护厂家继电器板子提供不同规格跳跃闭锁继电器启动电流的原因。
电焊机电缆本产品适用于二次侧对地电压交流不超过200V和脉动直流峰值400V电焊机用二次侧接线及连接电焊钳用。在一定条件下,也可用于传输2048kbit/s及以上的数字信号。HYA、HYAT用于架空、管道敷设。

3、产品型号规格及范围:产品型号规格范围使用场合MKVV,MKVVP,MKVVP20.5-10mm2,2-61芯适用于弱电控制系统或强电磁场干扰区MKVV22,MKVV200.5-10mm2,4-61芯MKVV32,MKVV300.5-10mm2,7-61芯MKVVR0.5-6mm2,2-61芯MK。
1. Ac rated voltage: U. /U (V series: 600/1000v, K series: 450/750v, B series: 450/750v) 2. The cable is the highest working temperature for a long time (1) the ene poly ethylene insulated and sheathed 坲 : 70 ℃ and 105 ℃ of two; Cross-linked polyethylene insulation: 90 ℃; (2) the fluorine plastic insulation and sheath: 220 ℃ and 260 ℃. 105 ℃ flame retardant poly (vinyl fluoride and fluorine plastic insulation sheath: 90 ℃ and 125 ℃. (3) low smoke low halogen flame retardant PVC insulated and sheathed: 70 ℃; Low smoke zero halogen flame retardant insulation and sheath: 90 ℃ and 125 ℃. 3. The lowest temperature: (1) flame retardant PVC insulated and sheathed: fixed installation - 40 ℃; The fixed installation - 15 ℃; (2) the fluorine plastic insulation and sheath: fixed installation - 60 ℃; The fixed installation - 20 ℃; 4. Cable temperature safety should not be below 0 ℃.
In order to evaluate the flame-retardant performance of wire cables, iec 60332-1, iec 60332-2 and iec 60332-3 were formulated respectively. Iec60332-1 and iec60332-2 are respectively used to evaluate the flame retardant capability of a single cable when it is laid on an incline and vertically (corresponding to GB12666.3 and GB12666.4 in China). Iec60332-3 (domestic equivalent to gb12666.5-90) is used to evaluate the flame retardant capability of beam cable when it is vertical, compared with that of beam cable when it is vertical.